Cascade Fill Calculator

How many breathing air cylinders your air storage can fill, and which compressor suits it.

How to use it. Work through steps 1 to 5. Fill in the yellow boxes, like this one 32, and pick from the yellow drop-downs. Your results update as you type.

Cylinders to fill

Fill station

CSA Z94.4 sets 300 psi a minute unless the SCBA maker states otherwise in writing.

Bleed, disconnect, swap and reconnect, one position at a time.

Air storage

Primary compressor

The primary compressor is the one compared against other models in the results.

Secondary compressors

Your results

Compare scenarios

Save what is on screen as scenario A or B, for example the current setup and a proposed one. Load brings a saved scenario back into the steps.

Bank pressure after the session

Dashed outline is the full charge. Solid is what is left after filling the session, or after the bank can no longer finish a fill.

Same storage, different bank layouts

Filling session

Bank fills and direct fills are both held to the maximum fill rate. A direct fill takes the cascade as far as it goes, then the compressor finishes it, and slows down if the compressor cannot keep up. The compressor is not recharging the bank during the session in this estimate.

Compressor options for this storage

Recharge is the time to put back the air used in one session, at the rated delivery. With more than one compressor, delivery, motor and cooling air are totals for all units, and noise is the loudest single unit. Noise is the maker’s published figure. Cooling air is what the room ventilation has to move while the compressor runs. Per-stage monitoring means temperature and pressure on every compression stage.

Fill by fill

Estimates for planning only. Uses the real behaviour of air at high pressure, not simple pressure times volume, at one steady temperature. Assumes the cascade is worked lowest bank first and each cylinder settles at the fill pressure, so heat from fast filling is ignored. Compressor output is taken as constant, although it falls near final pressure, so real recharge runs longer. Fill SCBA cylinders at the rate the SCBA maker states. Air quality testing, cylinder requalification and fill station certification are separate requirements.

Cascade Fill Calculator v2.0 · Updated 2026-11-06 · Tidal Flow Systems Inc.

Planning a fill room?
Send us your numbers and we will size the compressor, storage and fill station with you.

Talk to us

Bank filling and cascade filling

What is a bank?

A bank is a group of storage cylinders piped together and opened and closed as one. Your air storage can be set up as one bank, or split into two to four banks, each with its own valve on the fill station.

One bankSCBAall cylinders fall togetherBank filling (1 bank)

Every storage cylinder is connected together. Each SCBA cylinder equalizes with the whole bank, so the bank pressure drops a little with every fill. Once it falls below the fill pressure, the bank can no longer finish a fill, and the air left in it cannot be used until the compressor recharges it.

1st2ndlastSCBAeach bank has its own valveCascade filling (2 to 4 banks)

The storage is split into banks. Each fill starts on the lowest-pressure bank, then the operator switches up bank by bank, and the highest bank only tops the cylinder off. The lower banks keep doing useful work long after they could no longer finish a fill on their own.

Why it matters

  1. Cascade filling gets more full fills out of the same storage cylinders, because much more of the stored air is used.
  2. The fill station has to support it. A single-pressure fill station can only bank fill. Cascade filling needs a fill station with a valve for each bank.
  3. Either way, every fill is still held to the maximum fill rate set in step 2.