{"title":"Nardi Purification Systems","description":"\u003cp\u003eNardi breathing air purification. Filter Pac tower assemblies and replacement filter cartridges for clean, breathable air.\u003c\/p\u003e","products":[{"product_id":"nardi-filter-pac-atl","title":"Nardi Filter Pac ATL — Replacement Cartridge for Atlantic Series","description":"\u003cp\u003e\u003cstrong\u003eReplacement filter cartridge for the Nardi Atlantic Portable Breathing Air Compressor.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Filter Pac ATL is a drop-in purification cartridge that scrubs water vapour, oil aerosol, hydrocarbons, and odour from the air stream before it reaches your storage cylinder. Replacing it on schedule keeps your breathing air compliant with DIN EN 12021 (breathing air quality) and EN ISO 8573-1 (compressed air contaminants).\u003c\/p\u003e\n\n\u003ch3\u003eSelect the cartridge for your compressor\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eElectric\u003c\/strong\u003e\u003cbr\u003e\nStandard MC-AC media (Molecular Sieve + Activated Carbon). For the Atlantic Electric. With no combustion source upstream of the intake, there is no carbon monoxide risk and a standard cartridge is sufficient.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGasoline \/ Diesel\u003c\/strong\u003e\u003cbr\u003e\nMC-AC-HO media (Molecular Sieve + Activated Carbon + Hopcalite). Hopcalite is a catalyst that converts carbon monoxide to carbon dioxide. Required for any compressor driven by an internal combustion engine, which covers both the Atlantic Gasoline and Atlantic Diesel.\u003c\/p\u003e\n\n\u003ch3\u003eService interval\u003c\/h3\u003e\n\n\u003cp\u003eReplace the cartridge per the schedule in your Atlantic Operator's Manual, or sooner if the Atlantic's saturation indicator changes colour. Intervals shorten with high ambient humidity, polluted intake conditions, or high run hours.\u003c\/p\u003e\n\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eDIN EN 12021:2014 breathing air quality\u003c\/li\u003e\n  \u003cli\u003eEN ISO 8573-1 compressed air purity\u003c\/li\u003e\n  \u003cli\u003eCSA-certified for sale and use in Canada\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eDesigned exclusively for the Nardi Atlantic Series. Not interchangeable with the Pacific, Pacific E, or other Nardi families. If you operate a different Nardi model, contact us for the correct cartridge reference.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eEngineered in Italy. Made in Italy.\u003c\/em\u003e\u003c\/p\u003e","brand":"Nardi Compressori","offers":[{"title":"Electric","offer_id":49640308441327,"sku":"NRD-FP-ATL-ELEC","price":89.95,"currency_code":"CAD","in_stock":true},{"title":"Gasoline \/ Diesel","offer_id":49640308474095,"sku":"NRD-FP-ATL-GD","price":99.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/8547\/1983\/files\/01-hero-Atlantic-Filter.png?v=1776224883"},{"product_id":"nardi-filter-pac1-cartridge","title":"Nardi Filter PAC1 — Replacement Filter Cartridge for PAC1 Filter Towers","description":"\u003cp\u003e\u003cstrong\u003eReplacement filter cartridge for the Nardi PAC1 Purification Tower.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Filter PAC1 cartridge is a drop-in replacement that scrubs water vapour, oil aerosol, hydrocarbons, and odour from the air stream before it reaches your storage cylinder. Replacing it on schedule keeps your breathing air compliant with DIN EN 12021 (breathing air quality) and EN ISO 8573-1 (compressed air contaminants).\u003c\/p\u003e\n\n\u003ch3\u003eSelect the cartridge for your compressor\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eElectric\u003c\/strong\u003e\u003cbr\u003e\nStandard MC-AC media (Molecular Sieve + Activated Carbon). For any electric compressor driving a PAC1 tower (Pacific E, P, C, or M). Also fits industrial PAC1 installations. With no combustion source upstream of the intake, there is no carbon monoxide risk and a standard cartridge is sufficient.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGasoline \/ Diesel\u003c\/strong\u003e\u003cbr\u003e\nMC-AC-HO media (Molecular Sieve + Activated Carbon + Hopcalite). Hopcalite is a catalyst that converts carbon monoxide to carbon dioxide. Required for any compressor driven by an internal combustion engine, which covers the Pacific EG (gasoline), Pacific PG (gasoline), and Pacific DY (Yanmar diesel) when fitted with a PAC1 tower.\u003c\/p\u003e\n\n\u003ch3\u003eService interval\u003c\/h3\u003e\n\n\u003cp\u003eReplace the cartridge per the schedule in your compressor Operator's Manual, or sooner if the saturation indicator changes colour. Intervals shorten with high ambient humidity, polluted intake conditions, or high run hours.\u003c\/p\u003e\n\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eDIN EN 12021:2014 breathing air quality\u003c\/li\u003e\n  \u003cli\u003eEN ISO 8573-1 compressed air purity\u003c\/li\u003e\n  \u003cli\u003eCSA-certified for sale and use in Canada\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eThis cartridge fits the PAC1 tower. PAC1 is the standard purification tower on Pacific E, EG, P, PG, C (16\/23\/27\/30), DY (23\/27\/30), and M (23\/27\/30). It is also an order-time upgrade option on smaller Pacific configurations. Verify the model designation stamped on your tower before ordering — if your compressor was ordered or upgraded with a PAC2 or PAC3 tower, see the \u003ca href=\"\/products\/nardi-filter-pac2-cartridge\"\u003ePAC2 Replacement Cartridge\u003c\/a\u003e or \u003ca href=\"\/products\/nardi-filter-pac3-cartridge\"\u003ePAC3 Replacement Cartridge\u003c\/a\u003e. For Atlantic compressors, see the \u003ca href=\"\/products\/nardi-filter-pac-atl\"\u003eFilter Pac ATL Cartridge\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eNeed the full tower assembly?\u003c\/h3\u003e\n\n\u003cp\u003eThis product is the replacement cartridge only. If you need the PAC1 filter tower itself (configurable inlet, with or without pressure-maintaining valve, freestanding or wall-mount), see the \u003ca href=\"\/products\/nardi-filter-pac1-tower\"\u003eNardi Filter PAC1 Purification Tower Assembly\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eEngineered in Italy. Made in Italy.\u003c\/em\u003e\u003c\/p\u003e","brand":"Nardi Compressori","offers":[{"title":"Electric","offer_id":49640444756207,"sku":"NRD-FP-PAC1-ELEC","price":257.95,"currency_code":"CAD","in_stock":true},{"title":"Gasoline \/ Diesel","offer_id":49640444788975,"sku":"NRD-FP-PAC1-GD","price":268.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/8547\/1983\/files\/01-hero-PAC-Tower-Cutaway_8a903aeb-61c7-43f8-9fc9-3f4c78f4dfae.png?v=1776224763"},{"product_id":"nardi-filter-pac2-cartridge","title":"Nardi Filter PAC2 — Replacement Filter Cartridge for PAC2 Filter Towers","description":"\u003cp\u003e\u003cstrong\u003eReplacement filter cartridge for the Nardi PAC2 Purification Tower.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Filter PAC2 cartridge is a drop-in replacement that scrubs water vapour, oil aerosol, hydrocarbons, and odour from the air stream before it reaches your storage cylinder. Replacing it on schedule keeps your breathing air compliant with DIN EN 12021 (breathing air quality) and EN ISO 8573-1 (compressed air contaminants) at 1000 L\/min throughput.\u003c\/p\u003e\n\n\u003ch3\u003eSelect the cartridge for your compressor\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eElectric\u003c\/strong\u003e\u003cbr\u003e\nStandard MC-AC media (Molecular Sieve + Activated Carbon). For any electric compressor driving a PAC2 tower (Pacific C 35, M 35, M Nitrox 30, or any Pacific compressor upgraded to a PAC2 tower at order time). With no combustion source upstream of the intake, there is no carbon monoxide risk and a standard cartridge is sufficient.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGasoline \/ Diesel\u003c\/strong\u003e\u003cbr\u003e\nMC-AC-HO media (Molecular Sieve + Activated Carbon + Hopcalite). Hopcalite is a catalyst that converts carbon monoxide to carbon dioxide. Required for any compressor driven by an internal combustion engine when fitted with a PAC2 tower (Pacific DY 35 and any combustion-engine Pacific upgraded to PAC2).\u003c\/p\u003e\n\n\u003ch3\u003eService interval\u003c\/h3\u003e\n\n\u003cp\u003eReplace the cartridge per the schedule in your compressor Operator's Manual, or sooner if the saturation indicator changes colour. Intervals shorten with high ambient humidity, polluted intake conditions, or high run hours.\u003c\/p\u003e\n\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eDIN EN 12021:2014 breathing air quality\u003c\/li\u003e\n  \u003cli\u003eEN ISO 8573-1 compressed air purity\u003c\/li\u003e\n  \u003cli\u003eCSA-certified for sale and use in Canada\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eThis cartridge fits the PAC2 tower. PAC2 is the standard purification tower on Pacific C 35, M 35, DY 35, and M Nitrox 30. It is also offered as an upgrade on smaller Pacific configurations. Verify the model designation stamped on your tower before ordering — if your compressor was ordered or upgraded with a PAC1 or PAC3 tower, see the \u003ca href=\"\/products\/nardi-filter-pac1-cartridge\"\u003ePAC1 Replacement Cartridge\u003c\/a\u003e or \u003ca href=\"\/products\/nardi-filter-pac3-cartridge\"\u003ePAC3 Replacement Cartridge\u003c\/a\u003e. For Atlantic compressors, see the \u003ca href=\"\/products\/nardi-filter-pac-atl\"\u003eFilter Pac ATL Cartridge\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eNeed the full tower assembly?\u003c\/h3\u003e\n\n\u003cp\u003eThis product is the replacement cartridge only. If you need the PAC2 filter tower itself (configurable inlet, with or without pressure-maintaining valve, freestanding or wall-mount), see the \u003ca href=\"\/products\/nardi-filter-pac2-tower\"\u003eNardi Filter PAC2 Purification Tower Assembly\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eEngineered in Italy. Made in Italy.\u003c\/em\u003e\u003c\/p\u003e","brand":"Nardi Compressori","offers":[{"title":"Electric","offer_id":49640446132463,"sku":"NRD-FP-PAC2-ELEC","price":293.95,"currency_code":"CAD","in_stock":true},{"title":"Gasoline \/ Diesel","offer_id":49640446165231,"sku":"NRD-FP-PAC2-GD","price":310.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/8547\/1983\/files\/01-hero-PAC-Tower-Cutaway_fc97ed56-0a7a-4c81-9faa-0d53bbed731a.png?v=1776224716"},{"product_id":"nardi-filter-pac3-cartridge","title":"Nardi Filter PAC3 — Replacement Filter Cartridge for PAC3 Filter Towers","description":"\u003cp\u003e\u003cstrong\u003eReplacement filter cartridge for the Nardi PAC3 Purification Tower.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Filter PAC3 cartridge is a drop-in replacement that scrubs water vapour, oil aerosol, hydrocarbons, and odour from the air stream before it reaches your storage cylinder. Replacing it on schedule keeps your breathing air compliant with DIN EN 12021 (breathing air quality) and EN ISO 8573-1 (compressed air contaminants) at 1000 L\/min throughput per tower. Double- and triple-tower PAC3 installations consume two or three cartridges per service.\u003c\/p\u003e\n\n\u003ch3\u003eSelect the cartridge for your compressor\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eElectric\u003c\/strong\u003e\u003cbr\u003e\nStandard MC-AC media (Molecular Sieve + Activated Carbon). For any electric compressor driving a PAC3 tower (Pacific CX, MX, or any Pacific compressor upgraded to a PAC3 tower at order time). With no combustion source upstream of the intake, there is no carbon monoxide risk and a standard cartridge is sufficient.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGasoline \/ Diesel\u003c\/strong\u003e\u003cbr\u003e\nMC-AC-HO media (Molecular Sieve + Activated Carbon + Hopcalite). Hopcalite is a catalyst that converts carbon monoxide to carbon dioxide. Required for any compressor driven by an internal combustion engine when fitted with a PAC3 tower.\u003c\/p\u003e\n\n\u003ch3\u003eService interval\u003c\/h3\u003e\n\n\u003cp\u003eReplace each cartridge per the schedule in your compressor Operator's Manual, or sooner if the saturation indicator changes colour. Double- and triple-tower installations consume cartridges in proportion. Intervals shorten with high ambient humidity, polluted intake conditions, or high run hours.\u003c\/p\u003e\n\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eDIN EN 12021:2014 breathing air quality\u003c\/li\u003e\n  \u003cli\u003eEN ISO 8573-1 compressed air purity\u003c\/li\u003e\n  \u003cli\u003eCSA-certified for sale and use in Canada\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eThis cartridge fits the PAC3 tower (single, double, or triple configuration). PAC3 is the standard purification tower on Pacific CX 50\/60, MX 50, and the double-PAC3 configuration on CX 68\/85, MX 60\/60.4\/68\/85, and MX Nitrox 60N. It is also offered as an upgrade on smaller Pacific configurations. Verify the model designation stamped on your tower before ordering — if your compressor uses a PAC1 or PAC2 tower, see the \u003ca href=\"\/products\/nardi-filter-pac1-cartridge\"\u003ePAC1 Replacement Cartridge\u003c\/a\u003e or \u003ca href=\"\/products\/nardi-filter-pac2-cartridge\"\u003ePAC2 Replacement Cartridge\u003c\/a\u003e. For Atlantic compressors, see the \u003ca href=\"\/products\/nardi-filter-pac-atl\"\u003eFilter Pac ATL Cartridge\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eNeed the full tower assembly?\u003c\/h3\u003e\n\n\u003cp\u003eThis product is the replacement cartridge only. If you need the PAC3 filter tower itself (configurable inlet, with or without pressure-maintaining valve, freestanding, wall-mount, double-tower, or triple-tower), see the \u003ca href=\"\/products\/nardi-filter-pac3-tower\"\u003eNardi Filter PAC3 Purification Tower Assembly\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eEngineered in Italy. Made in Italy.\u003c\/em\u003e\u003c\/p\u003e","brand":"Nardi Compressori","offers":[{"title":"Electric","offer_id":49640447443183,"sku":"NRD-FP-PAC3-ELEC","price":327.95,"currency_code":"CAD","in_stock":true},{"title":"Gasoline \/ Diesel","offer_id":49640447475951,"sku":"NRD-FP-PAC3-GD","price":361.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/8547\/1983\/files\/01-hero-PAC-Tower-Cutaway.png?v=1776224676"},{"product_id":"nardi-filter-pac1-tower","title":"Nardi Filter PAC1 — Purification Tower Assembly","description":"\u003cp\u003e\u003cstrong\u003ePED-certified filter tower housing for Nardi high-pressure breathing air installations.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Filter PAC1 tower is the pressure vessel that holds the replacement filter cartridge. It includes a mechanical separator that spin-dries incoming air before filtration. Paired with a Nardi PAC1 cartridge, the tower delivers DIN EN 12021 and EN ISO 8573-1 compliant purification at 500 L\/min throughput.\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration options\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eInlet orientation.\u003c\/strong\u003e Left or right, selected to match your compressor's plumbing geometry. Outlet is fixed at the top of the tower.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePressure-Maintaining Valve.\u003c\/strong\u003e The PMV holds back-pressure in the tower so air dwells longer in the filter media. Recommended for breathing-air applications where saturation control matters. The Without-PMV configuration is offered for industrial use cases where downstream regulation handles pressure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting.\u003c\/strong\u003e Freestanding bolts to the compressor frame or floor. Wall-Mount comes pre-fitted to a wall bracket for fixed installations and is offered only in the With-PMV configuration. Wall-Mount is supplied without a safety valve (refer to your installation's existing safety relief).\u003c\/p\u003e\n\n\u003ch3\u003eCartridge sold separately\u003c\/h3\u003e\n\n\u003cp\u003eThe PAC1 tower requires a Nardi PAC1 replacement cartridge — Electric (MC-AC media) or Gasoline \/ Diesel (MC-AC-HO media with Hopcalite for CO conversion). See the \u003ca href=\"\/products\/nardi-filter-pac1-cartridge\"\u003eNardi Filter PAC1 Replacement Filter Cartridge\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eThe PAC1 is the standard purification tower on Pacific E, EG, P, PG, C (16\/23\/27\/30), DY (23\/27\/30), and M (23\/27\/30) compressors. Note that Pacific compressors ship with a PAC tower integrated — the standalone tower listed here is for installations that need a separate freestanding or wall-mount tower, or for tower replacement. For higher throughput, see the \u003ca href=\"\/products\/nardi-filter-pac2-tower\"\u003ePAC2 Tower\u003c\/a\u003e (1000 L\/min) or \u003ca href=\"\/products\/nardi-filter-pac3-tower\"\u003ePAC3 Tower\u003c\/a\u003e (1000 L\/min, expandable to 2000 L\/min in double-tower configuration).\u003c\/p\u003e\n\n\u003cp style=\"background:#f0f9ff;border-left:4px solid #00A8E8;padding:10px 14px;margin:0 0 16px;\"\u003eSee the \u003cstrong\u003eSpecifications\u003c\/strong\u003e tab for full technical specifications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eEngineered in Italy. Made in Italy.\u003c\/em\u003e\u003c\/p\u003e","brand":"Nardi Compressori","offers":[{"title":"Freestanding \/ Left \/ With PMV","offer_id":49640431091951,"sku":"NRD-FT-PAC1-FS-L-PMV","price":1982.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Right \/ With PMV","offer_id":49640815198447,"sku":"NRD-FT-PAC1-FS-R-PMV","price":1982.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Left \/ Without PMV","offer_id":49640815231215,"sku":"NRD-FT-PAC1-FS-L","price":1948.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Right \/ Without PMV","offer_id":49640815263983,"sku":"NRD-FT-PAC1-FS-R","price":1948.95,"currency_code":"CAD","in_stock":true},{"title":"Wall-Mount \/ Left \/ With PMV","offer_id":49640815296751,"sku":"NRD-FT-PAC1-WM-L-PMV","price":3124.95,"currency_code":"CAD","in_stock":true},{"title":"Wall-Mount \/ Right \/ With PMV","offer_id":49640815329519,"sku":"NRD-FT-PAC1-WM-R-PMV","price":3124.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/8547\/1983\/files\/01-hero-PAC-Tower-Cutaway_8a903aeb-61c7-43f8-9fc9-3f4c78f4dfae.png?v=1776224763"},{"product_id":"nardi-filter-pac2-tower","title":"Nardi Filter PAC2 — Purification Tower Assembly","description":"\u003cp\u003e\u003cstrong\u003ePED-certified filter tower housing for Nardi high-pressure breathing air installations.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Filter PAC2 tower is the pressure vessel that holds the replacement filter cartridge. It includes a mechanical separator that spin-dries incoming air before filtration. Paired with a Nardi PAC2 cartridge, the tower delivers DIN EN 12021 and EN ISO 8573-1 compliant purification at 1000 L\/min throughput.\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration options\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eInlet orientation.\u003c\/strong\u003e Left or right, selected to match your compressor's plumbing geometry. Outlet is fixed at the top of the tower.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePressure-Maintaining Valve.\u003c\/strong\u003e The PMV holds back-pressure in the tower so air dwells longer in the filter media. Recommended for breathing-air applications where saturation control matters. The Without-PMV configuration is offered for industrial use cases where downstream regulation handles pressure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting.\u003c\/strong\u003e Freestanding bolts to the compressor frame or floor. Wall-Mount comes pre-fitted to a wall bracket for fixed installations and is offered only in the With-PMV configuration. Wall-Mount is supplied without a safety valve (refer to your installation's existing safety relief).\u003c\/p\u003e\n\n\u003ch3\u003eCartridge sold separately\u003c\/h3\u003e\n\n\u003cp\u003eThe PAC2 tower requires a Nardi PAC2 replacement cartridge — Electric (MC-AC media) or Gasoline \/ Diesel (MC-AC-HO media with Hopcalite for CO conversion). See the \u003ca href=\"\/products\/nardi-filter-pac2-cartridge\"\u003eNardi Filter PAC2 Replacement Filter Cartridge\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eThe PAC2 is the standard purification tower on Pacific C 35, M 35, DY 35, and M Nitrox 30. It is also offered as an upgrade on Pacific E, EG, P, PG, C (16\/23\/27\/30), DY (23\/27\/30), and M (23\/27\/30) where higher throughput is required. Note that Pacific compressors ship with their PAC tower integrated — the standalone tower listed here is for separate installations or replacement. For larger installations, see the \u003ca href=\"\/products\/nardi-filter-pac3-tower\"\u003ePAC3 Tower\u003c\/a\u003e (1000 L\/min single, 2000 or 3000 L\/min in multi-tower). For smaller compressors, see the \u003ca href=\"\/products\/nardi-filter-pac1-tower\"\u003ePAC1 Tower\u003c\/a\u003e (500 L\/min).\u003c\/p\u003e\n\n\u003cp style=\"background:#f0f9ff;border-left:4px solid #00A8E8;padding:10px 14px;margin:0 0 16px;\"\u003eSee the \u003cstrong\u003eSpecifications\u003c\/strong\u003e tab for full technical specifications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eEngineered in Italy. Made in Italy.\u003c\/em\u003e\u003c\/p\u003e","brand":"Nardi Compressori","offers":[{"title":"Freestanding \/ Left \/ With PMV","offer_id":49640431485167,"sku":"NRD-FT-PAC2-FS-L-PMV","price":2167.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Right \/ With PMV","offer_id":49640838168815,"sku":"NRD-FT-PAC2-FS-R-PMV","price":2167.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Left \/ Without PMV","offer_id":49640838201583,"sku":"NRD-FT-PAC2-FS-L","price":2066.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Right \/ Without PMV","offer_id":49640838234351,"sku":"NRD-FT-PAC2-FS-R","price":2066.95,"currency_code":"CAD","in_stock":true},{"title":"Wall-Mount \/ Left \/ With PMV","offer_id":49640838267119,"sku":"NRD-FT-PAC2-WM-L-PMV","price":3343.95,"currency_code":"CAD","in_stock":true},{"title":"Wall-Mount \/ Right \/ With PMV","offer_id":49640838299887,"sku":"NRD-FT-PAC2-WM-R-PMV","price":3343.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/8547\/1983\/files\/01-hero-PAC-Tower-Cutaway_fc97ed56-0a7a-4c81-9faa-0d53bbed731a.png?v=1776224716"},{"product_id":"nardi-filter-pac3-tower","title":"Nardi Filter PAC3 — Purification Tower Assembly","description":"\u003cp\u003e\u003cstrong\u003ePED-certified filter tower housing for Nardi high-pressure breathing air installations — the largest single-tower configuration in the PAC range, with multi-tower wall-mount options for high-output installations.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Filter PAC3 tower is the pressure vessel that holds the replacement filter cartridge. It includes a mechanical separator that spin-dries incoming air before filtration. Paired with a Nardi PAC3 cartridge, the tower delivers DIN EN 12021 and EN ISO 8573-1 compliant purification at 1000 L\/min throughput per tower, expandable to 2000 L\/min in double-tower configuration and 3000 L\/min in triple-tower configuration.\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration options\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eInlet orientation.\u003c\/strong\u003e Left or right, selected to match your compressor's plumbing geometry. Outlet is fixed at the top of the tower. Multi-tower wall-mount configurations ship with Left inlet only.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePressure-Maintaining Valve.\u003c\/strong\u003e The PMV holds back-pressure in the tower so air dwells longer in the filter media. Recommended for breathing-air applications where saturation control matters. The Without-PMV configuration is offered for industrial use cases where downstream regulation handles pressure. Wall-mount and multi-tower configurations are supplied With-PMV only.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMounting.\u003c\/strong\u003e Freestanding bolts to the compressor frame or floor. Wall-Mount comes pre-fitted to a wall bracket for single-tower installations. Wall-Mount Double (2x PAC3) and Wall-Mount Triple (3x PAC3) are pre-fitted multi-tower configurations for high-throughput stationary installations. Wall-mount variants are supplied without a safety valve (refer to your installation's existing safety relief). Multi-tower configurations consume two or three cartridges per service interval respectively.\u003c\/p\u003e\n\n\u003ch3\u003eCartridge sold separately\u003c\/h3\u003e\n\n\u003cp\u003eThe PAC3 tower requires a Nardi PAC3 replacement cartridge — Electric (MC-AC media) or Gasoline \/ Diesel (MC-AC-HO media with Hopcalite for CO conversion). Double-tower configurations consume two cartridges per service, triple-tower consume three. See the \u003ca href=\"\/products\/nardi-filter-pac3-cartridge\"\u003eNardi Filter PAC3 Replacement Filter Cartridge\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\n\u003cp\u003eThe PAC3 (single) is the standard purification tower on Pacific CX 50 and CX 60, and Pacific MX 50. The PAC3 Double (PAC3 + PAC3) is the standard configuration on Pacific CX 68\/85 and Pacific MX 60\/60.4\/68\/85. The PAC3 Triple is offered for Pacific MX Nitrox 60N and other high-output installations. Note that Pacific compressors ship with their PAC tower integrated — the standalone tower listed here is for separate installations or replacement. For smaller compressors, see the \u003ca href=\"\/products\/nardi-filter-pac2-tower\"\u003ePAC2 Tower\u003c\/a\u003e (1000 L\/min, single only) or \u003ca href=\"\/products\/nardi-filter-pac1-tower\"\u003ePAC1 Tower\u003c\/a\u003e (500 L\/min, single only).\u003c\/p\u003e\n\n\u003cp style=\"background:#f0f9ff;border-left:4px solid #00A8E8;padding:10px 14px;margin:0 0 16px;\"\u003eSee the \u003cstrong\u003eSpecifications\u003c\/strong\u003e tab for full technical specifications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eEngineered in Italy. Made in Italy.\u003c\/em\u003e\u003c\/p\u003e","brand":"Nardi Compressori","offers":[{"title":"Freestanding \/ Left \/ With PMV","offer_id":49640431780079,"sku":"NRD-FT-PAC3-FS-L-PMV","price":2603.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Right \/ With PMV","offer_id":49640857174255,"sku":"NRD-FT-PAC3-FS-R-PMV","price":2603.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Left \/ Without PMV","offer_id":49640857207023,"sku":"NRD-FT-PAC3-FS-L","price":2519.95,"currency_code":"CAD","in_stock":true},{"title":"Freestanding \/ Right \/ Without PMV","offer_id":49640857239791,"sku":"NRD-FT-PAC3-FS-R","price":2519.95,"currency_code":"CAD","in_stock":true},{"title":"Wall-Mount \/ Left \/ With PMV","offer_id":49640857272559,"sku":"NRD-FT-PAC3-WM-L-PMV","price":3292.95,"currency_code":"CAD","in_stock":true},{"title":"Wall-Mount \/ Right \/ With PMV","offer_id":49640857305327,"sku":"NRD-FT-PAC3-WM-R-PMV","price":3292.95,"currency_code":"CAD","in_stock":true},{"title":"Wall-Mount Double \/ Left \/ With PMV","offer_id":49640857338095,"sku":"NRD-FT-PAC3-WM2-L-PMV","price":6585.95,"currency_code":"CAD","in_stock":true},{"title":"Wall-Mount Triple \/ Left \/ With PMV","offer_id":49640857370863,"sku":"NRD-FT-PAC3-WM3-L-PMV","price":9743.95,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0782\/8547\/1983\/files\/01-hero-PAC-Tower-Cutaway.png?v=1776224676"}],"url":"https:\/\/tidalflowsystems.com\/collections\/nardi-purification-systems.oembed","provider":"Tidal Flow Systems","version":"1.0","type":"link"}